Tried mounting a motion sensor at 7 feet in a garage and got zero triggers for a week
Last month I put a PIR sensor up high in a customer's garage in Mesa because I figured it would cut down on false alarms from his dog. Turned out the sensor barely caught anything at all, not even him walking to his truck, because the angle was so steep the detection zone skipped right over the floor. I dropped it down to about 6 feet and angled it flat, and it picked up every trip within 20 minutes of testing. Lesson was pretty simple: height kills the pattern more than I expected, and the spec sheet zone chart is worth actually reading. What height are you all running in garages with pets around?
That "height kills the pattern" line is dead on. I mounted one at 7 feet in my own garage and spent a week thinking the sensor was broken, since it never tripped when I walked under it. Dropped it to about 6 feet with a slight downward tilt and it caught me every single time after that. The spec sheet zone chart is no joke, the detection pattern comes out in a cone and up high it just shoots over everything. I keep mine around 6 feet now, and my lab mix still sets it off plenty, so the pet immunity is more about the angle than the height for me.